Home CompareHandler 125 vs IronMan 240
Handler 125 vs IronMan 240
Same fields. Each cell is that model's published text. A blank stays "Not published by manufacturer." The outlet chip does not hide either column.
| Spec | Handler 125 | IronMan 240 |
|---|---|---|
| Process | Flux-cored out of the box, and MIG after a regulator and shielding gas are added. The sheet calls it a constant-voltage DC welder. | MIG and flux-cored. Spool-gun connection is described for aluminum wire. |
| Output amp range | 25–130 A. | 30–280 A. |
| Rated duty cycle | 80 A at 25% duty cycle. The specifications table also prints 50 A at 60% and 40 A at 100%. | 200 A at 24 VDC, 60% duty cycle. |
| Input voltage and plug | 120 V. Amps input at rated output, 60 Hz: 21.3 A. The sheet says it operates on common 120-volt power and includes a power cord with plug. It does not name the plug or a breaker size. | 208 V and 240 V. Amperes input at rated load: 57.0 A at 208 V and 50.8 A at 240 V, on the 200 A, 60% row. A power cord with plug is included. The plug is not named. |
| Wire or rod size | Ready to weld with .030–.035 in. (0.8–0.9 mm) self-shielding flux-cored wire. With gas, .023–.030 in. (0.6–0.8 mm) solid wire. Stainless wire is mentioned for 18–12 gauge stainless with tri-mix gas. | The gun note on the sheet says .023–.045 in. (0.6–1.1 mm) wire, and the included drive roll is a dual-groove .030/.035 in. roll. Wire feed speed is 50–700 ipm. |
| Weight | 57.5 lb. | 186 lb. |
| Material thickness | Mild steel thickness range 24 ga.–3/16 in. The same page limits the gas-shielded example to 24 gauge–1/8 inch steel. | Mild steel thickness range 24 ga.–1/2 in. (13 mm). |