WeldFactsAmps, duty cycle, outlet

Home Models

Models

31 machines. Each table is what the manufacturer published, plus the URL and the date we read it.

Miller · 907838

Millermatic 142

100 A at 19 V, 60% duty cycle. 80 A at 18 V, 100% duty cycle.

120 V, 20 A, single-phase, 50/60 Hz.

Spec table

Miller · 907839

Millermatic 211 PRO

120 V: 110 A at 19.5 VDC, 60% duty cycle. 240 V: 160 A at 22.0 VDC, 60% duty cycle.

120 V: 27.0 A, single-phase, 50/60 Hz. 240 V: 28.9 A, single-phase, 50/60 Hz. The sheet says the cord uses MVP plugs for 120 V and 240 V and does not name a breaker size.

Spec table

Miller · 907321

Millermatic 252

200 A at 24 VDC, 60% duty cycle. 250 A at 26.5 VDC, 40% duty cycle.

208/240 V, single-phase, 60 Hz, or 230/460/575 V, single-phase, 60 Hz. On the 208/240 V row, amps input at the 200 A, 60% rating are 57.0 A at 208 V and 50.8 A at 240 V.

Spec table

Miller · 907734

Millermatic 255

230 A at 25.5 V, 60% duty cycle.

208–240 V, single-phase. Auto-Line 208–575 V, single-phase. The quick specs do not print input amperes.

Spec table

Miller · 907840

Multimatic 215 PRO

120 V: 110 A at 19.5 VDC, 60% duty cycle. 240 V: 160 A at 22.0 VDC, 60% duty cycle, and 215 A at 24.8 VDC, 30% duty cycle.

120 or 240 V, single-phase, 50/60 Hz. MVP plugs for 120 V and 240 V are included. Input amperes are not in the quick specs.

Spec table

Miller · 907757

Multimatic 220 AC/DC

MIG: 120 V, 105 A at 19.2 V, 60% duty cycle; 240 V, 200 A at 24 V, 20% duty cycle and 170 A at 21.5 V, 40% duty cycle. Stick: 120 V, 90 A at 23.6 V, 40%; 240 V, 200 A at 28.4 V, 15%. TIG: 120 V, 130 A at 15.2 V, 40%; 240 V, 210 A at 18.4 V, 20%.

120/240 V, single-phase, 50/60 Hz. Amps input at rated output: MIG 23.3 A at 120 V and 27.2 A at the 200 A / 20% 240 V rating; stick 24.5 A at 120 V and 31.3 A at 240 V; TIG 24.0 A at 120 V and 22.4 A at 240 V.

Spec table

Miller · 907780

Multimatic 235

MIG: 170 A at 22.5 V, 60% duty cycle. Stick: 150 A at 26 V, 60% duty cycle. TIG: 180 A at 17.2 V, 60% duty cycle.

240 V, single-phase. Input amperes are not in the quick specs.

Spec table

Miller · 907728

Multimatic 255

MIG: 230 A at 25.5 V, 60% duty cycle. Stick: 200 A at 28 V, 60% duty cycle. TIG: 275 A at 21 V, 60% duty cycle.

Auto-Line 208–575 V, single-phase. Input amperes are not in the quick specs.

Spec table

Miller · 907909

Thunderbolt 210 MV

120 V: 65 A at 60% duty cycle and 50 A at 100% duty cycle. 240 V: 135 A at 60% duty cycle and 105 A at 100% duty cycle.

1-phase power, 120 V or 240 V, 50/60 Hz. Maximum amps input at rated load output: 27.8 A at 120 V and 44.9 A at 240 V. The cord includes multi-voltage plugs for 120 V and 240 V.

Spec table

Miller · 907711

Maxstar 161 STH

TIG, 120 V: 90 A at 13.6 VDC, 100% duty cycle, and 130 A at 15.2 VDC, 30%. TIG, 240 V: 110 A at 14.4 VDC, 100%, and 160 A at 16.4 VDC, 20%. Stick, 120 V: 60 A at 22.4 VDC, 100%, and 90 A at 23.6 VDC, 30%. Stick, 240 V: 110 A at 24.4 VDC, 100%, and 160 A at 26.4 VDC, 20%.

120–240 V, 1-phase. Amps input at the higher duty-point ratings: TIG 22.6 A at 120 V and 15.05 A at 240 V; stick 23.16 A at 120 V and 22.55 A at 240 V. Separate 120 V and 240 V power cords are included.

Spec table

Miller · 907911

Syncrowave 212

Quick specs lead with 130 A at 15.2 V, 60% duty cycle. The table adds, at 60%: 120 V DC TIG 110 A at 14.4 V, and 240 V DC stick 120 A at 24.8 V. It also prints 210 A at 20% and 120 A at 100% on the AC/DC TIG duty column, without tying those two lines to one voltage.

120–240 V, 1-phase, 50/60 Hz. Amps input at rated output in the table: 18.8 A for 120 V DC TIG and 11.8 A for 240 V DC TIG. The 240 V DC stick row prints 16.3 A.

Spec table

Miller · 907816

Dynasty 210

210 A at 18.4 V, 60% duty cycle.

120–480 V, 3-phase or 1-phase. The quick specs do not print input amperes.

Spec table

Hobart · 500573

Handler 125

80 A at 25% duty cycle. The specifications table also prints 50 A at 60% and 40 A at 100%.

120 V. Amps input at rated output, 60 Hz: 21.3 A. The sheet says it operates on common 120-volt power and includes a power cord with plug. It does not name the plug or a breaker size.

Spec table

Hobart · 500582

Handler 140EZ

90 A at 18.5 VDC, 30% duty cycle.

120-volt power. Amps input at rated output, 60 Hz, 115 V column: 20 A. A power cord with plug is included. The plug type is not named.

Spec table

Hobart · 500553

Handler 210MVP

115 V: 90 A at 19 VDC, 20% duty cycle. 230 V: 150 A at 23 VDC, 30% duty cycle.

115 V or 230 V, 60 Hz. Amps input at rated output: 20 A at 115 V and 24 A at 230 V. The cord includes 5-15P (115 V, 15 A) and 6-50P (230 V, 50 A) MVP plugs.

Spec table

Hobart · 500588

Handler 210i

120 V, 15 A: 45 A at 16.3 VDC, 100% duty cycle. 120 V, 20 A: 90 A at 18.5 VDC, 25% duty cycle, and 60 A at 17.0 VDC, 100% duty cycle. 240 V: 210 A at 24.5 VDC, 25% duty cycle, and 105 A at 19.3 VDC, 100% duty cycle.

120 V or 240 V, 50/60 Hz, with an included adapter for both. Amps input at rated output: 13.8 A on the 120 V, 15 A row; 27.6 A on the 120 V, 20 A row; 44.3 A on 240 V.

Spec table

Hobart · 500574

IronMan 240

200 A at 24 VDC, 60% duty cycle.

208 V and 240 V. Amperes input at rated load: 57.0 A at 208 V and 50.8 A at 240 V, on the 200 A, 60% row. A power cord with plug is included. The plug is not named.

Spec table

Hobart · 500578

Multi-Handler 200

At 30% duty cycle: MIG 110 A at 19.5 V on 120 V and 165 A at 22.2 V on 240 V; DC TIG 105 A at 14.2 V on 120 V and 165 A at 16.6 V on 240 V; stick 90 A at 23.6 V on 120 V and 140 A at 25.6 V on 240 V.

120 V or 240 V, 50/60 Hz. MVP plugs: 5-15P (120 V, 15 A) and 6-50P (240 V, 50 A). Amps input at rated output, MIG: 23.0 A at 120 V and 19.0 A at 240 V. DC TIG: 16.7 A and 14.7 A. Stick: 22.0 A and 17.9 A.

Spec table

Lincoln Electric · K4876-1

Power MIG 215 MPi

215 A / 24.8 V / 30%. The specifications table prints that one duty-cycle figure beside input power 120/230/1/60. 215 A is above the printed 120 V output range of 20–140 A.

120/230/1/60. Input current at rated output: 120 VAC, 15 A effective and 22 A max; 230 VAC, 15.9 A effective and 29 A max.

Spec table

Lincoln Electric · K5126-1

Square Wave TIG 200

120 V TIG: 125 A/25%, 100 A/40%, 85 A/60%. 120 V stick: 75 A/20%, 65 A/60%. 230 V TIG: 200 A/25%, 160 A/40%, 130 A/60%. 230 V stick: 170 A/20%, 100 A/60%.

120/1/50/60 and 230/1/50/60. Input current at those rated outputs runs from 14 A to 21 A on 120 V and from 13 A to 25 A on 230 V. The highest 120 V figure is 21 A and the highest 230 V figure is 25 A. 120/230 V input cords are included.

Spec table

Lincoln Electric · K3520-1

Power MIG 260

250 A / 26.5 V / 40%.

208/230/460/575 V, 1-phase, 60 Hz. Input current at rated output: 59/55/27/21 A in that voltage order. The 230 V figure is 55 A. This check treats that 230 V figure as the 240 V outlet class.

Spec table

Lincoln Electric · K3963-1

Power MIG 210 MP

MIG: 120 V, 100 A / 19.0 V / 40%. 230 V, 200 A / 24 V / 25%.

120/1/60 and 230/1/60. Effective input current at rated output: 15 A at 120 V and 14.7 A at 230 V. 120 V and 230 V input cables are included with K3963-1.

Spec table

ESAB

Rebel EMP 215ic

MIG, 230 V: 205 A / 24.25 V at 25% and 235 A / 26 V at 15%. MIG, 120 V, 20 A breaker: 130 A / 20.5 V at 20%. TIG, 230 V: 180 A / 17.2 V at 30%. Stick, 230 V: 180 A / 27.2 V at 25%. The table prints more duty points at 40%, 60%, and 100%.

120 V or 230 V, 1-phase, 50/60 Hz, ±10%. Imax MIG: 20.8 A on a 15 A breaker and 28.6 A on a 20 A breaker at 120 V; 30 A at 230 V (27.6 A at 25% duty cycle). The installation guide’s maximum recommended time-delay fuse or breaker is 30 A, and the maximum normal fuse is 50 A, for both supply voltages. Input current at maximum output in that guide is 30 A.

Spec table

ESAB · 0558012702

Rebel EMP 235ic

At 104°F (40°C): MIG 120 A / 19 V at 40% on 120 V and 235 A / 26 V at 40% on 230 V. Stick 90 A / 23.6 V at 40% on 120 V and 210 A / 28.4 V at 25% on 230 V. TIG 130 A / 15.2 V at 40% on 120 V and 240 A / 19.6 V at 40% on 230 V.

Primary voltage 120 VAC and 208/230 VAC, 1-phase, 50/60 Hz. Supply range 90–270 VAC. Supply plug 230 V, NEMA 6-50P. A separate accessory is a 230 V to 120 V, 15 A power adapter (W4014000). Input amperes are not in the specifications table.

Spec table

PrimeWeld

TIG225X

TIG: 40% at max output, and 100% at 108 A on 120 V or 155 A on 240 V. Stick: 40% at max output, and 100% at 76 A on 120 V or 139 A on 240 V.

120 V / 240 V, single-phase, 50/60 Hz. Input amperes and a plug name are not in the specifications list.

Spec table

PrimeWeld

TIG325X

TIG: 40% at 325 A, 60% at 280 A, 100% at 250 A. Stick: 40% at 250 A, 60% at 220 A, 100% at 180 A. The duty lines are not split by voltage.

120 V / 240 V, single-phase, 50/60 Hz. Input amperes are not in the specifications list.

Spec table

PrimeWeld

TIG230

TIG: 35% at 230 A, 60% at 175 A, 100% at 136 A. Stick: 35% at 200 A, 60% at 152 A, 100% at 118 A. The duty lines are not split by voltage.

90–275 V, 50–60 Hz. That range covers a 120 V outlet and a 240 V outlet. Input amperes are not in the specifications block.

Spec table

PrimeWeld

MIG285

MIG: 30% at 285 A on 240 V and 30% at 120 A on 120 V. Stick: 30% at 250 A on 240 V and 30% at 120 A on 120 V. TIG: 30% at 250 A on 240 V and 30% at 120 A on 120 V.

1-phase, 120 V/240 V. Max inrush (I1max), columns MIG / stick / TIG: 120 V 34.2 / 42.5 / 25.3 A, and 240 V 57.4 / 53.5 / 35.7 A. Max rated (I1eff): 120 V 18.7 / 23.3 / 13.9 A, and 240 V 27.4 / 29.3 / 19.6 A.

Spec table

PrimeWeld

TIG200

Duty cycle not published.

Dual-voltage 120/240 V input. Input amperes are not in that description.

Spec table

Harbor Freight · 57862

Unlimited 200

120 V: GMAW/FCAW 40% at 90 A, SMAW 40% at 70 A, GTAW 40% at 90 A. 240 V: GMAW/FCAW 15% at 200 A, SMAW 15% at 170 A, GTAW 15% at 200 A.

120/240 VAC, 60 Hz. Current input at 120 V: GMAW/FCAW 23 A, SMAW 22 A, GTAW 18 A. At 240 V: 32 A, 31 A, and 26 A.

Spec table

Harbor Freight · 58828

Unlimited 140

GMAW/FCAW 30% at 90 A. SMAW 40% at 75 A. GTAW 20% at 110 A.

120 VAC / 60 Hz. Current input: GMAW/FCAW 21 A, SMAW 21.3 A, GTAW 20.5 A.

Spec table