Models
31 machines. Each table is what the manufacturer published, plus the URL and the date we read it.
Miller · 907838
Millermatic 142
100 A at 19 V, 60% duty cycle. 80 A at 18 V, 100% duty cycle.
120 V, 20 A, single-phase, 50/60 Hz.
Spec table
Miller · 907839
Millermatic 211 PRO
120 V: 110 A at 19.5 VDC, 60% duty cycle. 240 V: 160 A at 22.0 VDC, 60% duty cycle.
120 V: 27.0 A, single-phase, 50/60 Hz. 240 V: 28.9 A, single-phase, 50/60 Hz. The sheet says the cord uses MVP plugs for 120 V and 240 V and does not name a breaker size.
Spec table
Miller · 907321
Millermatic 252
200 A at 24 VDC, 60% duty cycle. 250 A at 26.5 VDC, 40% duty cycle.
208/240 V, single-phase, 60 Hz, or 230/460/575 V, single-phase, 60 Hz. On the 208/240 V row, amps input at the 200 A, 60% rating are 57.0 A at 208 V and 50.8 A at 240 V.
Spec table
Miller · 907734
Millermatic 255
230 A at 25.5 V, 60% duty cycle.
208–240 V, single-phase. Auto-Line 208–575 V, single-phase. The quick specs do not print input amperes.
Spec table
Miller · 907840
Multimatic 215 PRO
120 V: 110 A at 19.5 VDC, 60% duty cycle. 240 V: 160 A at 22.0 VDC, 60% duty cycle, and 215 A at 24.8 VDC, 30% duty cycle.
120 or 240 V, single-phase, 50/60 Hz. MVP plugs for 120 V and 240 V are included. Input amperes are not in the quick specs.
Spec table
Miller · 907757
Multimatic 220 AC/DC
MIG: 120 V, 105 A at 19.2 V, 60% duty cycle; 240 V, 200 A at 24 V, 20% duty cycle and 170 A at 21.5 V, 40% duty cycle. Stick: 120 V, 90 A at 23.6 V, 40%; 240 V, 200 A at 28.4 V, 15%. TIG: 120 V, 130 A at 15.2 V, 40%; 240 V, 210 A at 18.4 V, 20%.
120/240 V, single-phase, 50/60 Hz. Amps input at rated output: MIG 23.3 A at 120 V and 27.2 A at the 200 A / 20% 240 V rating; stick 24.5 A at 120 V and 31.3 A at 240 V; TIG 24.0 A at 120 V and 22.4 A at 240 V.
Spec table
Miller · 907780
Multimatic 235
MIG: 170 A at 22.5 V, 60% duty cycle. Stick: 150 A at 26 V, 60% duty cycle. TIG: 180 A at 17.2 V, 60% duty cycle.
240 V, single-phase. Input amperes are not in the quick specs.
Spec table
Miller · 907728
Multimatic 255
MIG: 230 A at 25.5 V, 60% duty cycle. Stick: 200 A at 28 V, 60% duty cycle. TIG: 275 A at 21 V, 60% duty cycle.
Auto-Line 208–575 V, single-phase. Input amperes are not in the quick specs.
Spec table
Miller · 907909
Thunderbolt 210 MV
120 V: 65 A at 60% duty cycle and 50 A at 100% duty cycle. 240 V: 135 A at 60% duty cycle and 105 A at 100% duty cycle.
1-phase power, 120 V or 240 V, 50/60 Hz. Maximum amps input at rated load output: 27.8 A at 120 V and 44.9 A at 240 V. The cord includes multi-voltage plugs for 120 V and 240 V.
Spec table
Miller · 907711
Maxstar 161 STH
TIG, 120 V: 90 A at 13.6 VDC, 100% duty cycle, and 130 A at 15.2 VDC, 30%. TIG, 240 V: 110 A at 14.4 VDC, 100%, and 160 A at 16.4 VDC, 20%. Stick, 120 V: 60 A at 22.4 VDC, 100%, and 90 A at 23.6 VDC, 30%. Stick, 240 V: 110 A at 24.4 VDC, 100%, and 160 A at 26.4 VDC, 20%.
120–240 V, 1-phase. Amps input at the higher duty-point ratings: TIG 22.6 A at 120 V and 15.05 A at 240 V; stick 23.16 A at 120 V and 22.55 A at 240 V. Separate 120 V and 240 V power cords are included.
Spec table
Miller · 907911
Syncrowave 212
Quick specs lead with 130 A at 15.2 V, 60% duty cycle. The table adds, at 60%: 120 V DC TIG 110 A at 14.4 V, and 240 V DC stick 120 A at 24.8 V. It also prints 210 A at 20% and 120 A at 100% on the AC/DC TIG duty column, without tying those two lines to one voltage.
120–240 V, 1-phase, 50/60 Hz. Amps input at rated output in the table: 18.8 A for 120 V DC TIG and 11.8 A for 240 V DC TIG. The 240 V DC stick row prints 16.3 A.
Spec table
Miller · 907816
Dynasty 210
210 A at 18.4 V, 60% duty cycle.
120–480 V, 3-phase or 1-phase. The quick specs do not print input amperes.
Spec table
Hobart · 500573
Handler 125
80 A at 25% duty cycle. The specifications table also prints 50 A at 60% and 40 A at 100%.
120 V. Amps input at rated output, 60 Hz: 21.3 A. The sheet says it operates on common 120-volt power and includes a power cord with plug. It does not name the plug or a breaker size.
Spec table
Hobart · 500582
Handler 140EZ
90 A at 18.5 VDC, 30% duty cycle.
120-volt power. Amps input at rated output, 60 Hz, 115 V column: 20 A. A power cord with plug is included. The plug type is not named.
Spec table
Hobart · 500553
Handler 210MVP
115 V: 90 A at 19 VDC, 20% duty cycle. 230 V: 150 A at 23 VDC, 30% duty cycle.
115 V or 230 V, 60 Hz. Amps input at rated output: 20 A at 115 V and 24 A at 230 V. The cord includes 5-15P (115 V, 15 A) and 6-50P (230 V, 50 A) MVP plugs.
Spec table
Hobart · 500588
Handler 210i
120 V, 15 A: 45 A at 16.3 VDC, 100% duty cycle. 120 V, 20 A: 90 A at 18.5 VDC, 25% duty cycle, and 60 A at 17.0 VDC, 100% duty cycle. 240 V: 210 A at 24.5 VDC, 25% duty cycle, and 105 A at 19.3 VDC, 100% duty cycle.
120 V or 240 V, 50/60 Hz, with an included adapter for both. Amps input at rated output: 13.8 A on the 120 V, 15 A row; 27.6 A on the 120 V, 20 A row; 44.3 A on 240 V.
Spec table
Hobart · 500574
IronMan 240
200 A at 24 VDC, 60% duty cycle.
208 V and 240 V. Amperes input at rated load: 57.0 A at 208 V and 50.8 A at 240 V, on the 200 A, 60% row. A power cord with plug is included. The plug is not named.
Spec table
Hobart · 500578
Multi-Handler 200
At 30% duty cycle: MIG 110 A at 19.5 V on 120 V and 165 A at 22.2 V on 240 V; DC TIG 105 A at 14.2 V on 120 V and 165 A at 16.6 V on 240 V; stick 90 A at 23.6 V on 120 V and 140 A at 25.6 V on 240 V.
120 V or 240 V, 50/60 Hz. MVP plugs: 5-15P (120 V, 15 A) and 6-50P (240 V, 50 A). Amps input at rated output, MIG: 23.0 A at 120 V and 19.0 A at 240 V. DC TIG: 16.7 A and 14.7 A. Stick: 22.0 A and 17.9 A.
Spec table
Lincoln Electric · K4876-1
Power MIG 215 MPi
215 A / 24.8 V / 30%. The specifications table prints that one duty-cycle figure beside input power 120/230/1/60. 215 A is above the printed 120 V output range of 20–140 A.
120/230/1/60. Input current at rated output: 120 VAC, 15 A effective and 22 A max; 230 VAC, 15.9 A effective and 29 A max.
Spec table
Lincoln Electric · K5126-1
Square Wave TIG 200
120 V TIG: 125 A/25%, 100 A/40%, 85 A/60%. 120 V stick: 75 A/20%, 65 A/60%. 230 V TIG: 200 A/25%, 160 A/40%, 130 A/60%. 230 V stick: 170 A/20%, 100 A/60%.
120/1/50/60 and 230/1/50/60. Input current at those rated outputs runs from 14 A to 21 A on 120 V and from 13 A to 25 A on 230 V. The highest 120 V figure is 21 A and the highest 230 V figure is 25 A. 120/230 V input cords are included.
Spec table
Lincoln Electric · K3520-1
Power MIG 260
250 A / 26.5 V / 40%.
208/230/460/575 V, 1-phase, 60 Hz. Input current at rated output: 59/55/27/21 A in that voltage order. The 230 V figure is 55 A. This check treats that 230 V figure as the 240 V outlet class.
Spec table
Lincoln Electric · K3963-1
Power MIG 210 MP
MIG: 120 V, 100 A / 19.0 V / 40%. 230 V, 200 A / 24 V / 25%.
120/1/60 and 230/1/60. Effective input current at rated output: 15 A at 120 V and 14.7 A at 230 V. 120 V and 230 V input cables are included with K3963-1.
Spec table
ESAB
Rebel EMP 215ic
MIG, 230 V: 205 A / 24.25 V at 25% and 235 A / 26 V at 15%. MIG, 120 V, 20 A breaker: 130 A / 20.5 V at 20%. TIG, 230 V: 180 A / 17.2 V at 30%. Stick, 230 V: 180 A / 27.2 V at 25%. The table prints more duty points at 40%, 60%, and 100%.
120 V or 230 V, 1-phase, 50/60 Hz, ±10%. Imax MIG: 20.8 A on a 15 A breaker and 28.6 A on a 20 A breaker at 120 V; 30 A at 230 V (27.6 A at 25% duty cycle). The installation guide’s maximum recommended time-delay fuse or breaker is 30 A, and the maximum normal fuse is 50 A, for both supply voltages. Input current at maximum output in that guide is 30 A.
Spec table
ESAB · 0558012702
Rebel EMP 235ic
At 104°F (40°C): MIG 120 A / 19 V at 40% on 120 V and 235 A / 26 V at 40% on 230 V. Stick 90 A / 23.6 V at 40% on 120 V and 210 A / 28.4 V at 25% on 230 V. TIG 130 A / 15.2 V at 40% on 120 V and 240 A / 19.6 V at 40% on 230 V.
Primary voltage 120 VAC and 208/230 VAC, 1-phase, 50/60 Hz. Supply range 90–270 VAC. Supply plug 230 V, NEMA 6-50P. A separate accessory is a 230 V to 120 V, 15 A power adapter (W4014000). Input amperes are not in the specifications table.
Spec table
PrimeWeld
TIG225X
TIG: 40% at max output, and 100% at 108 A on 120 V or 155 A on 240 V. Stick: 40% at max output, and 100% at 76 A on 120 V or 139 A on 240 V.
120 V / 240 V, single-phase, 50/60 Hz. Input amperes and a plug name are not in the specifications list.
Spec table
PrimeWeld
TIG325X
TIG: 40% at 325 A, 60% at 280 A, 100% at 250 A. Stick: 40% at 250 A, 60% at 220 A, 100% at 180 A. The duty lines are not split by voltage.
120 V / 240 V, single-phase, 50/60 Hz. Input amperes are not in the specifications list.
Spec table
PrimeWeld
TIG230
TIG: 35% at 230 A, 60% at 175 A, 100% at 136 A. Stick: 35% at 200 A, 60% at 152 A, 100% at 118 A. The duty lines are not split by voltage.
90–275 V, 50–60 Hz. That range covers a 120 V outlet and a 240 V outlet. Input amperes are not in the specifications block.
Spec table
PrimeWeld
MIG285
MIG: 30% at 285 A on 240 V and 30% at 120 A on 120 V. Stick: 30% at 250 A on 240 V and 30% at 120 A on 120 V. TIG: 30% at 250 A on 240 V and 30% at 120 A on 120 V.
1-phase, 120 V/240 V. Max inrush (I1max), columns MIG / stick / TIG: 120 V 34.2 / 42.5 / 25.3 A, and 240 V 57.4 / 53.5 / 35.7 A. Max rated (I1eff): 120 V 18.7 / 23.3 / 13.9 A, and 240 V 27.4 / 29.3 / 19.6 A.
Spec table
PrimeWeld
TIG200
Duty cycle not published.
Dual-voltage 120/240 V input. Input amperes are not in that description.
Spec table
Harbor Freight · 57862
Unlimited 200
120 V: GMAW/FCAW 40% at 90 A, SMAW 40% at 70 A, GTAW 40% at 90 A. 240 V: GMAW/FCAW 15% at 200 A, SMAW 15% at 170 A, GTAW 15% at 200 A.
120/240 VAC, 60 Hz. Current input at 120 V: GMAW/FCAW 23 A, SMAW 22 A, GTAW 18 A. At 240 V: 32 A, 31 A, and 26 A.
Spec table
Harbor Freight · 58828
Unlimited 140
GMAW/FCAW 30% at 90 A. SMAW 40% at 75 A. GTAW 20% at 110 A.
120 VAC / 60 Hz. Current input: GMAW/FCAW 21 A, SMAW 21.3 A, GTAW 20.5 A.
Spec table