WeldFactsSheet numbers only

Home CompareHandler 125 vs MIG285

Handler 125 vs MIG285

Same fields. Each cell is that model's published text. A blank stays "Not published by manufacturer." The outlet chip does not hide either column.

Spec Handler 125 MIG285
Process Flux-cored out of the box, and MIG after a regulator and shielding gas are added. The sheet calls it a constant-voltage DC welder. The specifications table says output type MIG, lift TIG, and stick. The overview also names flux core.
Output amp range 25–130 A. Max rated output: MIG 285 A, TIG 250 A, stick 250 A. The duty table prints MIG 285 A on 240 V and 120 A on 120 V, and stick and TIG 250 A on 240 V and 120 A on 120 V.
Rated duty cycle 80 A at 25% duty cycle. The specifications table also prints 50 A at 60% and 40 A at 100%. MIG: 30% at 285 A on 240 V and 30% at 120 A on 120 V. Stick: 30% at 250 A on 240 V and 30% at 120 A on 120 V. TIG: 30% at 250 A on 240 V and 30% at 120 A on 120 V.
Input voltage and plug 120 V. Amps input at rated output, 60 Hz: 21.3 A. The sheet says it operates on common 120-volt power and includes a power cord with plug. It does not name the plug or a breaker size. 1-phase, 120 V/240 V. Max inrush (I1max), columns MIG / stick / TIG: 120 V 34.2 / 42.5 / 25.3 A, and 240 V 57.4 / 53.5 / 35.7 A. Max rated (I1eff): 120 V 18.7 / 23.3 / 13.9 A, and 240 V 27.4 / 29.3 / 19.6 A.
Wire or rod size Ready to weld with .030–.035 in. (0.8–0.9 mm) self-shielding flux-cored wire. With gas, .023–.030 in. (0.6–0.8 mm) solid wire. Stainless wire is mentioned for 18–12 gauge stainless with tri-mix gas. Not published by manufacturer
Weight 57.5 lb. The page says “weighing under 60 lbs.” It does not print a single net-weight number.
Material thickness Mild steel thickness range 24 ga.–3/16 in. The same page limits the gas-shielded example to 24 gauge–1/8 inch steel. The overview says the 285 A output can weld materials up to 5/8 inch thick.

Outlet check, Handler 125 · Outlet check, MIG285