WeldFactsSheet numbers only

Home CompareHandler 125 vs Power MIG 210 MP

Handler 125 vs Power MIG 210 MP

Same fields. Each cell is that model's published text. A blank stays "Not published by manufacturer." The outlet chip does not hide either column.

Spec Handler 125 Power MIG 210 MP
Process Flux-cored out of the box, and MIG after a regulator and shielding gas are added. The sheet calls it a constant-voltage DC welder. MIG, stick, TIG, and flux-cored. The rated-output column is labeled MIG.
Output amp range 25–130 A. 120 V: 20–140 A DC, max OCV 56. 230 V: 20–220 A DC, max OCV 56. Wire feed speed 50–500 ipm (1.3–12.7 m/min).
Rated duty cycle 80 A at 25% duty cycle. The specifications table also prints 50 A at 60% and 40 A at 100%. MIG: 120 V, 100 A / 19.0 V / 40%. 230 V, 200 A / 24 V / 25%.
Input voltage and plug 120 V. Amps input at rated output, 60 Hz: 21.3 A. The sheet says it operates on common 120-volt power and includes a power cord with plug. It does not name the plug or a breaker size. 120/1/60 and 230/1/60. Effective input current at rated output: 15 A at 120 V and 14.7 A at 230 V. 120 V and 230 V input cables are included with K3963-1.
Wire or rod size Ready to weld with .030–.035 in. (0.8–0.9 mm) self-shielding flux-cored wire. With gas, .023–.030 in. (0.6–0.8 mm) solid wire. Stainless wire is mentioned for 18–12 gauge stainless with tri-mix gas. Included drive rolls are 0.025–0.030 in. (0.6–0.8 mm) and 0.035 in. (0.9 mm), plus 0.030–0.045 in. (0.8–1.1 mm) knurled drive rolls. The specifications table itself does not print a wire-capacity range.
Weight 57.5 lb. 40 lb (18 kg).
Material thickness Mild steel thickness range 24 ga.–3/16 in. The same page limits the gas-shielded example to 24 gauge–1/8 inch steel. Not published by manufacturer

Outlet check, Handler 125 · Outlet check, Power MIG 210 MP