WeldFactsSheet numbers only

Home CompareHandler 125 vs Rebel EMP 215ic

Handler 125 vs Rebel EMP 215ic

Same fields. Each cell is that model's published text. A blank stays "Not published by manufacturer." The outlet chip does not hide either column.

Spec Handler 125 Rebel EMP 215ic
Process Flux-cored out of the box, and MIG after a regulator and shielding gas are added. The sheet calls it a constant-voltage DC welder. GMAW (MIG), GTAW (TIG), and SMAW (stick). Flux-cored wire is listed in the wire-diameter table.
Output amp range 25–130 A. MIG setting range: 15 A / 14.75 V to 130 A / 20.5 V on 120 V, and to 235 A / 26.0 V on 230 V. TIG: 5 A to 130 A on 120 V and to 200 A on 230 V. Stick: 6 A to 130 A on 120 V and 16 A to 180 A on 230 V.
Rated duty cycle 80 A at 25% duty cycle. The specifications table also prints 50 A at 60% and 40 A at 100%. MIG, 230 V: 205 A / 24.25 V at 25% and 235 A / 26 V at 15%. MIG, 120 V, 20 A breaker: 130 A / 20.5 V at 20%. TIG, 230 V: 180 A / 17.2 V at 30%. Stick, 230 V: 180 A / 27.2 V at 25%. The table prints more duty points at 40%, 60%, and 100%.
Input voltage and plug 120 V. Amps input at rated output, 60 Hz: 21.3 A. The sheet says it operates on common 120-volt power and includes a power cord with plug. It does not name the plug or a breaker size. 120 V or 230 V, 1-phase, 50/60 Hz, ±10%. Imax MIG: 20.8 A on a 15 A breaker and 28.6 A on a 20 A breaker at 120 V; 30 A at 230 V (27.6 A at 25% duty cycle). The installation guide’s maximum recommended time-delay fuse or breaker is 30 A, and the maximum normal fuse is 50 A, for both supply voltages. Input current at maximum output in that guide is 30 A.
Wire or rod size Ready to weld with .030–.035 in. (0.8–0.9 mm) self-shielding flux-cored wire. With gas, .023–.030 in. (0.6–0.8 mm) solid wire. Stainless wire is mentioned for 18–12 gauge stainless with tri-mix gas. Mild steel solid wire .023–.035 in. (0.6–0.9 mm). Stainless solid wire .030–.035 in. (0.8–0.9 mm). Flux-cored wire .030–.045 in. (0.8–1.1 mm). Aluminum .030–3/64 in. (0.8–1.2 mm). Spool size 4–8 in.
Weight 57.5 lb. 42 lb (19.1 kg). Dimensions 23 × 9 × 16 in.
Material thickness Mild steel thickness range 24 ga.–3/16 in. The same page limits the gas-shielded example to 24 gauge–1/8 inch steel. Not published by manufacturer

Outlet check, Handler 125 · Outlet check, Rebel EMP 215ic