WeldFactsSheet numbers only

Home CompareHandler 125 vs TIG200

Handler 125 vs TIG200

Same fields. Each cell is that model's published text. A blank stays "Not published by manufacturer." The outlet chip does not hide either column.

Spec Handler 125 TIG200
Process Flux-cored out of the box, and MIG after a regulator and shielding gas are added. The sheet calls it a constant-voltage DC welder. DC TIG and stick.
Output amp range 25–130 A. On 240 V: TIG 190 A and stick 185 A. On 120 V: TIG 145 A and stick 140 A. The lower limit is 10 A for either process.
Rated duty cycle 80 A at 25% duty cycle. The specifications table also prints 50 A at 60% and 40 A at 100%. Not published by manufacturer
Input voltage and plug 120 V. Amps input at rated output, 60 Hz: 21.3 A. The sheet says it operates on common 120-volt power and includes a power cord with plug. It does not name the plug or a breaker size. Dual-voltage 120/240 V input. Input amperes are not in that description.
Wire or rod size Ready to weld with .030–.035 in. (0.8–0.9 mm) self-shielding flux-cored wire. With gas, .023–.030 in. (0.6–0.8 mm) solid wire. Stainless wire is mentioned for 18–12 gauge stainless with tri-mix gas. Not published by manufacturer
Weight 57.5 lb. Not published by manufacturer
Material thickness Mild steel thickness range 24 ga.–3/16 in. The same page limits the gas-shielded example to 24 gauge–1/8 inch steel. 7/16-inch steel in a single pass is tied to the 190 A, 240 V TIG sentence. The 10 A floor is described as mild enough for 24-gauge sheet metal. A 120 V thickness is not printed.

Outlet check, Handler 125 · Outlet check, TIG200