WeldFactsSheet numbers only

Home CompareHandler 125 vs TIG230

Handler 125 vs TIG230

Same fields. Each cell is that model's published text. A blank stays "Not published by manufacturer." The outlet chip does not hide either column.

Spec Handler 125 TIG230
Process Flux-cored out of the box, and MIG after a regulator and shielding gas are added. The sheet calls it a constant-voltage DC welder. AC/DC TIG and stick. The page lists nine AC waveforms, including square, sine, triangle, and hybrid.
Output amp range 25–130 A. TIG 2–230 A. Stick 10–200 A.
Rated duty cycle 80 A at 25% duty cycle. The specifications table also prints 50 A at 60% and 40 A at 100%. TIG: 35% at 230 A, 60% at 175 A, 100% at 136 A. Stick: 35% at 200 A, 60% at 152 A, 100% at 118 A. The duty lines are not split by voltage.
Input voltage and plug 120 V. Amps input at rated output, 60 Hz: 21.3 A. The sheet says it operates on common 120-volt power and includes a power cord with plug. It does not name the plug or a breaker size. 90–275 V, 50–60 Hz. That range covers a 120 V outlet and a 240 V outlet. Input amperes are not in the specifications block.
Wire or rod size Ready to weld with .030–.035 in. (0.8–0.9 mm) self-shielding flux-cored wire. With gas, .023–.030 in. (0.6–0.8 mm) solid wire. Stainless wire is mentioned for 18–12 gauge stainless with tri-mix gas. Not published by manufacturer
Weight 57.5 lb. 46 lb. Dimensions 22 in. long, 8 in. wide, 16 in. high.
Material thickness Mild steel thickness range 24 ga.–3/16 in. The same page limits the gas-shielded example to 24 gauge–1/8 inch steel. Not published by manufacturer

Outlet check, Handler 125 · Outlet check, TIG230