Spec Handler 140EZ Rebel EMP 215ic
Process MIG and flux-cored. The included drive roll has grooves for solid wire and flux-cored wire, and the machine includes a gas solenoid and regulator. GMAW (MIG), GTAW (TIG), and SMAW (stick). Flux-cored wire is listed in the wire-diameter table.
Output amp range 30–140 A. MIG setting range: 15 A / 14.75 V to 130 A / 20.5 V on 120 V, and to 235 A / 26.0 V on 230 V. TIG: 5 A to 130 A on 120 V and to 200 A on 230 V. Stick: 6 A to 130 A on 120 V and 16 A to 180 A on 230 V.
Rated duty cycle 90 A at 18.5 VDC, 30% duty cycle. MIG, 230 V: 205 A / 24.25 V at 25% and 235 A / 26 V at 15%. MIG, 120 V, 20 A breaker: 130 A / 20.5 V at 20%. TIG, 230 V: 180 A / 17.2 V at 30%. Stick, 230 V: 180 A / 27.2 V at 25%. The table prints more duty points at 40%, 60%, and 100%.
Input voltage and plug 120-volt power. Amps input at rated output, 60 Hz, 115 V column: 20 A. A power cord with plug is included. The plug type is not named. 120 V or 230 V, 1-phase, 50/60 Hz, ±10%. Imax MIG: 20.8 A on a 15 A breaker and 28.6 A on a 20 A breaker at 120 V; 30 A at 230 V (27.6 A at 25% duty cycle). The installation guide’s maximum recommended time-delay fuse or breaker is 30 A, and the maximum normal fuse is 50 A, for both supply voltages. Input current at maximum output in that guide is 30 A.
Wire or rod size Quick Select drive roll for .024 in. (0.6 mm) or .030/.035 in. (0.8/0.9 mm) solid wire, and .030/.035 in. (0.8/0.9 mm) flux-cored wire. Mild steel solid wire .023–.035 in. (0.6–0.9 mm). Stainless solid wire .030–.035 in. (0.8–0.9 mm). Flux-cored wire .030–.045 in. (0.8–1.1 mm). Aluminum .030–3/64 in. (0.8–1.2 mm). Spool size 4–8 in.
Weight Not published by manufacturer 42 lb (19.1 kg). Dimensions 23 × 9 × 16 in.
Material thickness Mild steel thickness range 24 ga.–3/16 in., described as a single pass, with thicker material by multiple passes and prep. Not published by manufacturer

Outlet check, Handler 140EZ · Outlet check, Rebel EMP 215ic