Home CompareHandler 210i vs Unlimited 200
Handler 210i vs Unlimited 200
Same fields. Each cell is that model's published text. A blank stays "Not published by manufacturer." The outlet chip does not hide either column.
| Spec | Handler 210i | Unlimited 200 |
|---|---|---|
| Process | MIG and flux-cored. The included drive roll covers solid and flux-cored wire, and spool-gun circuitry is described for aluminum wire. | GMAW/FCAW, SMAW, and GTAW. |
| Output amp range | 120 V: 30–140 A. 240 V: 30–210 A. | 120 V: GMAW/FCAW 30–140 A, SMAW 15–70 A, GTAW 15–90 A. 240 V: GMAW/FCAW 30–200 A, SMAW 15–170 A, GTAW 15–200 A. |
| Rated duty cycle | 120 V, 15 A: 45 A at 16.3 VDC, 100% duty cycle. 120 V, 20 A: 90 A at 18.5 VDC, 25% duty cycle, and 60 A at 17.0 VDC, 100% duty cycle. 240 V: 210 A at 24.5 VDC, 25% duty cycle, and 105 A at 19.3 VDC, 100% duty cycle. | 120 V: GMAW/FCAW 40% at 90 A, SMAW 40% at 70 A, GTAW 40% at 90 A. 240 V: GMAW/FCAW 15% at 200 A, SMAW 15% at 170 A, GTAW 15% at 200 A. |
| Input voltage and plug | 120 V or 240 V, 50/60 Hz, with an included adapter for both. Amps input at rated output: 13.8 A on the 120 V, 15 A row; 27.6 A on the 120 V, 20 A row; 44.3 A on 240 V. | 120/240 VAC, 60 Hz. Current input at 120 V: GMAW/FCAW 23 A, SMAW 22 A, GTAW 18 A. At 240 V: 32 A, 31 A, and 26 A. |
| Wire or rod size | Quick Select drive roll for .024 in. (0.6 mm) or .030/.035 in. (0.8/0.9 mm) solid wire, and .030/.035 in. (0.8/0.9 mm) flux-cored wire. | Solid core .025 / .030 / .035 in. Flux-cored .030 / .035 in. Wire speed 80–400 IPM. Spool capacity up to 12 lb. |
| Weight | 26 lb. The sheet says the machine weighs only 26 pounds. | Not published by manufacturer |
| Material thickness | Mild steel thickness range 24 ga.–3/8 in., in a single pass, with thicker material by multiple passes. | Not published by manufacturer |