WeldFactsSheet numbers only

Home CompareHandler 210MVP vs TIG225X

Handler 210MVP vs TIG225X

Same fields. Each cell is that model's published text. A blank stays "Not published by manufacturer." The outlet chip does not hide either column.

Spec Handler 210MVP TIG225X
Process MIG and flux-cored. Spool-gun circuitry is described for aluminum wire. A gas solenoid and regulator are included. AC/DC TIG and stick. The page tells the operator to use AC for aluminum and magnesium and DC for steel, stainless, and most other metals.
Output amp range 115 V: 25–140 A. 230 V: 25–210 A. TIG 10–225 A. Stick 10–180 A.
Rated duty cycle 115 V: 90 A at 19 VDC, 20% duty cycle. 230 V: 150 A at 23 VDC, 30% duty cycle. TIG: 40% at max output, and 100% at 108 A on 120 V or 155 A on 240 V. Stick: 40% at max output, and 100% at 76 A on 120 V or 139 A on 240 V.
Input voltage and plug 115 V or 230 V, 60 Hz. Amps input at rated output: 20 A at 115 V and 24 A at 230 V. The cord includes 5-15P (115 V, 15 A) and 6-50P (230 V, 50 A) MVP plugs. 120 V / 240 V, single-phase, 50/60 Hz. Input amperes and a plug name are not in the specifications list.
Wire or rod size Quick Select drive roll for .024 in. (0.6 mm) or .030/.035 in. (0.8/0.9 mm) solid wire, and .030/.035 in. (0.8/0.9 mm) flux-cored wire. Not published by manufacturer
Weight 79 lb. (35.8 kg). 41 lb (18.5 kg).
Material thickness Mild steel thickness range 24 ga.–3/8 in., in a single pass. The sheet says thicker material is run with multiple passes and does not print that second maximum. The page says it can weld materials up to 1/2 inch thick.

Outlet check, Handler 210MVP · Outlet check, TIG225X