WeldFactsSheet numbers only

Home CompareMaxstar 161 STH vs Handler 210i

Maxstar 161 STH vs Handler 210i

Same fields. Each cell is that model's published text. A blank stays "Not published by manufacturer." The outlet chip does not hide either column.

Spec Maxstar 161 STH Handler 210i
Process Stick (SMAW), Lift-Arc TIG (GTAW), high-frequency TIG (GTAW), and pulsed TIG (GTAW-P). High frequency and pulse are marked STH model only. MIG and flux-cored. The included drive roll covers solid and flux-cored wire, and spool-gun circuitry is described for aluminum wire.
Output amp range 120 V: 5–130 A DC TIG and 20–90 A DC stick. 240 V: 5–160 A DC TIG and 20–160 A DC stick. 120 V: 30–140 A. 240 V: 30–210 A.
Rated duty cycle TIG, 120 V: 90 A at 13.6 VDC, 100% duty cycle, and 130 A at 15.2 VDC, 30%. TIG, 240 V: 110 A at 14.4 VDC, 100%, and 160 A at 16.4 VDC, 20%. Stick, 120 V: 60 A at 22.4 VDC, 100%, and 90 A at 23.6 VDC, 30%. Stick, 240 V: 110 A at 24.4 VDC, 100%, and 160 A at 26.4 VDC, 20%. 120 V, 15 A: 45 A at 16.3 VDC, 100% duty cycle. 120 V, 20 A: 90 A at 18.5 VDC, 25% duty cycle, and 60 A at 17.0 VDC, 100% duty cycle. 240 V: 210 A at 24.5 VDC, 25% duty cycle, and 105 A at 19.3 VDC, 100% duty cycle.
Input voltage and plug 120–240 V, 1-phase. Amps input at the higher duty-point ratings: TIG 22.6 A at 120 V and 15.05 A at 240 V; stick 23.16 A at 120 V and 22.55 A at 240 V. Separate 120 V and 240 V power cords are included. 120 V or 240 V, 50/60 Hz, with an included adapter for both. Amps input at rated output: 13.8 A on the 120 V, 15 A row; 27.6 A on the 120 V, 20 A row; 44.3 A on 240 V.
Wire or rod size Not published by manufacturer Quick Select drive roll for .024 in. (0.6 mm) or .030/.035 in. (0.8/0.9 mm) solid wire, and .030/.035 in. (0.8/0.9 mm) flux-cored wire.
Weight 13 lb. (5.9 kg). 26 lb. The sheet says the machine weighs only 26 pounds.
Material thickness Not published by manufacturer Mild steel thickness range 24 ga.–3/8 in., in a single pass, with thicker material by multiple passes.

Outlet check, Maxstar 161 STH · Outlet check, Handler 210i