Spec Rebel EMP 215ic Unlimited 200
Process GMAW (MIG), GTAW (TIG), and SMAW (stick). Flux-cored wire is listed in the wire-diameter table. GMAW/FCAW, SMAW, and GTAW.
Output amp range MIG setting range: 15 A / 14.75 V to 130 A / 20.5 V on 120 V, and to 235 A / 26.0 V on 230 V. TIG: 5 A to 130 A on 120 V and to 200 A on 230 V. Stick: 6 A to 130 A on 120 V and 16 A to 180 A on 230 V. 120 V: GMAW/FCAW 30–140 A, SMAW 15–70 A, GTAW 15–90 A. 240 V: GMAW/FCAW 30–200 A, SMAW 15–170 A, GTAW 15–200 A.
Rated duty cycle MIG, 230 V: 205 A / 24.25 V at 25% and 235 A / 26 V at 15%. MIG, 120 V, 20 A breaker: 130 A / 20.5 V at 20%. TIG, 230 V: 180 A / 17.2 V at 30%. Stick, 230 V: 180 A / 27.2 V at 25%. The table prints more duty points at 40%, 60%, and 100%. 120 V: GMAW/FCAW 40% at 90 A, SMAW 40% at 70 A, GTAW 40% at 90 A. 240 V: GMAW/FCAW 15% at 200 A, SMAW 15% at 170 A, GTAW 15% at 200 A.
Input voltage and plug 120 V or 230 V, 1-phase, 50/60 Hz, ±10%. Imax MIG: 20.8 A on a 15 A breaker and 28.6 A on a 20 A breaker at 120 V; 30 A at 230 V (27.6 A at 25% duty cycle). The installation guide’s maximum recommended time-delay fuse or breaker is 30 A, and the maximum normal fuse is 50 A, for both supply voltages. Input current at maximum output in that guide is 30 A. 120/240 VAC, 60 Hz. Current input at 120 V: GMAW/FCAW 23 A, SMAW 22 A, GTAW 18 A. At 240 V: 32 A, 31 A, and 26 A.
Wire or rod size Mild steel solid wire .023–.035 in. (0.6–0.9 mm). Stainless solid wire .030–.035 in. (0.8–0.9 mm). Flux-cored wire .030–.045 in. (0.8–1.1 mm). Aluminum .030–3/64 in. (0.8–1.2 mm). Spool size 4–8 in. Solid core .025 / .030 / .035 in. Flux-cored .030 / .035 in. Wire speed 80–400 IPM. Spool capacity up to 12 lb.
Weight 42 lb (19.1 kg). Dimensions 23 × 9 × 16 in. Not published by manufacturer
Material thickness Not published by manufacturer Not published by manufacturer

Outlet check, Rebel EMP 215ic · Outlet check, Unlimited 200