Spec Handler 210i Rebel EMP 235ic
Process MIG and flux-cored. The included drive roll covers solid and flux-cored wire, and spool-gun circuitry is described for aluminum wire. MIG, TIG, and stick. The wire table includes flux-cored diameters in the ordering copy: up to .052 in. cored wire.
Output amp range 120 V: 30–140 A. 240 V: 30–210 A. Current range 5–150 A on 120 V and 5–250 A on 230 V. Maximum output 250 A / 30 V.
Rated duty cycle 120 V, 15 A: 45 A at 16.3 VDC, 100% duty cycle. 120 V, 20 A: 90 A at 18.5 VDC, 25% duty cycle, and 60 A at 17.0 VDC, 100% duty cycle. 240 V: 210 A at 24.5 VDC, 25% duty cycle, and 105 A at 19.3 VDC, 100% duty cycle. At 104°F (40°C): MIG 120 A / 19 V at 40% on 120 V and 235 A / 26 V at 40% on 230 V. Stick 90 A / 23.6 V at 40% on 120 V and 210 A / 28.4 V at 25% on 230 V. TIG 130 A / 15.2 V at 40% on 120 V and 240 A / 19.6 V at 40% on 230 V.
Input voltage and plug 120 V or 240 V, 50/60 Hz, with an included adapter for both. Amps input at rated output: 13.8 A on the 120 V, 15 A row; 27.6 A on the 120 V, 20 A row; 44.3 A on 240 V. Primary voltage 120 VAC and 208/230 VAC, 1-phase, 50/60 Hz. Supply range 90–270 VAC. Supply plug 230 V, NEMA 6-50P. A separate accessory is a 230 V to 120 V, 15 A power adapter (W4014000). Input amperes are not in the specifications table.
Wire or rod size Quick Select drive roll for .024 in. (0.6 mm) or .030/.035 in. (0.8/0.9 mm) solid wire, and .030/.035 in. (0.8/0.9 mm) flux-cored wire. Mild steel .023–.035 in. (0.6–0.9 mm). Stainless .030–.035 in. (0.8–0.9 mm). Aluminum .030–.045 in. (0.8–1.2 mm). The introduction also says up to .045 in. solid wire, up to .052 in. cored wire, rods up to 5/32 in., and TIG rods up to 3/16 in. Spools 4, 8, and 12 in.
Weight 26 lb. The sheet says the machine weighs only 26 pounds. Specifications table: 63 lb (28.6 kg). The same brochure’s introduction says “weighing in at 53 lbs. (24 kg).”
Material thickness Mild steel thickness range 24 ga.–3/8 in., in a single pass, with thicker material by multiple passes. Maximum plate thickness 1/2 in. (12.7 mm).

Outlet check, Handler 210i · Outlet check, Rebel EMP 235ic